ISOTOPE VS. TUBE 

IN GENERAL, X-RAY TUBES WILL PROVIDE

          Lower limits of elemental detection (LOD)

          Lower limits of elemental quantification (LOQ)

          Lighter element capabilities in air (Mg)

          Great improvement in bias, precision and accuracy

          Quicker testing times

          Better repeatability

          Flexibility in transportation (domestic & international)

          No disposal fees or dangerous goods

          No registration, leak testing, CNSC compliance

          Safer and Easier to use over isotope units

          Reduced overall cost of ownership. No disposal fees or source replacements.

          Remove instability issues with sources.


INNOV-X PIONEERED X-RAY TUBE ANALYSIS

X-ray tubes have long been proven to be the most versatile, high performing excitation sources for XRF analysis. Innov-X Systems harnessed that energy and integrated it with the rapidly evolving technology of portable and wireless computers to introduce the first handheld, miniature x-ray tube-based XRF.


WHY X-RAY TUBES INSTEAD OF ISOTOPES

          Avoids future isotope headaches: New Nuclear Regulatory Commission (NRC) regulations are coming! Portable gauges utilizing radioactive isotopes are specifically targeted.

          End-user taking personal responsibility for day-to-day isotope compliance.

          Double lockup requirements for travel with isotopes.

          Increased fines for lost or stolen isotope analyzers - a real concern for modern, highly portable isotope systems!

          Escalating isotope disposal costs - radioactive waste disposal facilities are shutting down at the same time demand for disposal space is skyrocketing due to non-isotope options.


EPA SUPPORTS TUBES

"X-ray tubes have higher radiation output, no intrinsic lifetime limit, produce constant output over their lifetime, and do not have the disposal problems of radioactive sources."

-EPA Method 6200, published 1998



X-RAY TUBES - START FAST AND STAY FAST

          No loss of speed or throughput - Eliminates progressive loss of testing speed and precision from decaying sources.

          Single test analyzes all RCRA and other metals - higher sample throughput by eliminating requirement to analyze sample with multiple isotopes.

          Published NIOSH data for elements Cr, Pb, Ni, Co, Fe, Cu and Zn demonstrates excellent performance compared to existing isotope-based analyzers.


X-RAYS - SAFE, EASY AND COST EFFECTIVE


Without radioactive sources!

          Eliminates isotope licensing - makes interstate travel simple!

          Eliminates the regulatory baggage of radioactive materials control - no wipe tests, no travel restrictions, easy to transport.

          Eliminates the liability of isotope control, theft and disposal.